Research on high-sensitivity fiber-optical Fabry-Perot thermal flow velocity sensing technology based on the vernier effect
DOI:
CSTR:
Author:
Affiliation:

1.School of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao 066004, China; 2.Hebei Key Laboratory of MicroNano Precision Optical Sensing and Measurement Technology, Qinhuangdao 066004, China; 3.College of Information Science and Engineering, Northeastern University, Shenyang 110819, China

Clc Number:

TH815

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    To address the issues of low sensitivity in high-velocity regions and limited upper measurement range in traditional fiber-optic thermal flow sensors, a high-sensitivity fiber-optic Fabry-Perot thermal flow velocity sensing method based on the Vernier effect and thermosensitive materials is proposed. The fiber-optic sensor employed in this method is fabricated by splicing a single-mode fiber (SMF) with a hollow-core fiber (HCF) filled with thermosensitive material at its end. The sensor achieves the first-stage sensitivity enhancement by utilizing the high temperature sensitivity of the thermosensitive material. Simultaneously, the cascaded Fabry-Perot interferometer (FPI) structure formed between the SMF and the thermosensitive material end-face creates the Vernier effect, which enables the second-stage sensitivity enhancement through the amplification characteristics of the Vernier effect. Through this two-stage enhancement mechanism, the sensor achieves improved flow velocity sensitivity in high-velocity regions and an extended measurement range. The sensing performance of the proposed high-sensitivity fiber-optic Fabry-Perot thermal flow velocity sensing method was theoretically analyzed using PDMS as the thermosensitive material. Concurrently, the sensor fabrication process was investigated, resulting in the successful fabrication of a physical sensor prototype. Experimental analysis was conducted to evaluate key sensing performance metrics, including sensitivity, maximum measurable flow velocity, and repeatability. The experimental results demonstrate that the sensor exhibits a temperature sensitivity of 1.399 nm/℃ and achieves a maximum measurable flow velocity of 25 m/s. Within the range of 17~25 m/s, the sensor′s response curve shows excellent linearity (R2=0.99), with a flow velocity sensitivity of 1.45 nm/(m/s). The repeatability deviation of sensitivity is only 1.24%, indicating excellent consistency. Owing to its high sensitivity, extended velocity measurement range, and compact form factor, this sensing method shows strong potential for industrial applications.

    Reference
    Related
    Cited by
Get Citation
Related Videos

Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:
  • Revised:
  • Adopted:
  • Online: September 09,2025
  • Published:
Article QR Code