Research on distributed doubleparameter sensing characteristics of long chirped fiber bragg grating
DOI:
Author:
Affiliation:

Beijing Key Laboratory for Optoelectronics Measurement Technology, Beijing Engineering Research Center of Optoelectronic Information and Instruments, Beijing Information Science and Technology University, Beijing 100016, China

Clc Number:

TH823

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    The traditional precise position sensor is susceptible to electromagnetic interference and poor compatibility of composite materials under complicated conditions. A distributed position and pressure doubleparameter sensor is proposed based on long chirped fiber grating. A doubleparameter sensing model of long chirped fiber grating is established, and the theoretical model of doubleparameter sensor based on long chirped fiber grating is validated by numerical simulation. A doubleparameter sensing system for long chirped fiber gratings is developed. The experimental results show that the sensor has a spatial resolution of 50 μm and a linearity of 99.99% for the position measurement in the full scale range. This sensor also has a sensitivity coefficient of 0.003 399 dB/N and a linearity of 99.8% for the transverse force. This sensor can be applied to precise lateral force and location measurement in complex environment.