基于分割环阵的 CFRP 分层缺陷超声全聚焦成像
DOI:
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

TH878 TB553

基金项目:

国家商用飞机制造工程技术研究中心创新基金(COMAC-SFGS-2022-1812)项目资助


Ultrasonic total focusing method of carbon fiber reinforced plastics delamination defects based on segmented annular arrays
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    碳纤维复合材料在钻孔加工时易产生分层缺陷,分层缺陷严重影响了构件的力学性能,存在严重的安全隐患。 针对碳纤 维复合材料孔边分层缺陷的检测,提出一种基于分割环形阵列的 1/ 4 矩阵全聚焦成像方法。 设计了 R4×S8、R3×S12、R3×S16 和 R4×S12 四种分割环形阵列结构,通过数值仿真对比分析了各阵列的聚焦声场特点,最终确定分割环阵探头为 5 MHz 的 R4×S12 探 头。 使用该探头对碳纤维复合材料孔边分层试块的上层、中层、下层缺陷进行全矩阵采集,利用 VTK 工具包分别进行全矩阵三维 成像和 1/ 4 矩阵三维成像。 结果表明,1/ 4 矩阵方法比全矩阵方法三维成像的缺陷对比度更高,1/ 4 矩阵方法的缺陷尺寸表征误 差更小,误差不超过 6% 。 与全矩阵成像相比,1/ 4 矩阵成像信噪比提升范围为 3. 43~7. 61 dB,有效提升了图像质量。

    Abstract:

    Carbon fiber-reinforced plastics are prone to delamination defects during drilling and processing, and the delamination defects seriously affect the mechanical properties of the components, and there are serious safety hazards. For the detection of delamination defects at the hole edge of carbon fiber-reinforced plastics, a 1 / 4 matrix total focusing method based on the segmented annular arrays is proposed. Four structures of segmented annular arrays, R4×S8, R3×S12, R3×S16, and R4×S12, are designed. The characteristics of the focused sound field of each array are analyzed by numerical simulation comparisons, and the segmented annular array probe is finally determined to be the 5 MHz R4×S12 probe. By using this probe, the full-matrix capture of the upper, middle, and lower layer defects of the hole-edge delamination specimens of carbon fiber composites is performed, and the full-matrix 3D imaging and 1 / 4-matrix 3D imaging are implemented by using the VTK toolkit, respectively. The results show that the 1 / 4-matrix method has higher defect contrast than the full-matrix method for 3D imaging. The defects size characterization error of the 1 / 4-matrix method is smaller, with an error of no more than 6% . Compared with that of full-matrix imaging, the signal-to-noise ratio enhancement of the 1 / 4-matrix imaging is in the range of 3. 43~ 7. 61 dB, which effectively improves the image quality

    参考文献
    相似文献
    引证文献
引用本文

杨 宁,陆铭慧,张 萍,朱 颖,张毅萍.基于分割环阵的 CFRP 分层缺陷超声全聚焦成像[J].仪器仪表学报,2024,44(1):200-210

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2024-04-10
  • 出版日期: