    摘要:

    针对常规红外双波段场景模拟器多基于单数字微镜器件(DMD)设计、不能对两个波段进行差异化调制、只满足仿真测试的工作波段需求、实用性差的问题,提出了一种基于双DMD的双通道、共口径、两档变焦、结构紧凑的红外中/长波场景模拟器,并对投影系统、照明系统、双色合束镜等主要部分进行了详细的光机结构设计。光学引擎采用远心光路直接照明DMD靶面,利用空间立体式布局来避免不同光路间的干扰,且使用两块小型金属平面反射镜压缩照明光路以提高系统集成度;采用半运动学弹性夹持方式固定合束镜,重点计算了弹簧夹为得到最小预载应发生的偏转量及其在材料中形成的弯曲应力;利用MATLAB求解出两波段黑体的工作温度,并拟合出经光学系统后两波段辐射出射度与全红外波段黑体辐射出射度的比例关系ψ(T)曲线。测试结果表明,黑体温度为850 K时达到最高表观温度要求,中波图像对比度为250∶1,长波图像对比度为14∶1,满足现阶段红外中/长波场景模拟器的使用要求。

    Abstract:

    Regular infrared dualband scene simulators are mostly designed with single DMD, which cannot modulate the two wave bands severally. The single DMD based design can only meet the requirements of working wave band, but is not that practical. To solve this problem, a dualDMD based dualchannel coaperture switchzoom compactstructure MWIR (Medium Wave Infrared)/LWIR(Long Wave Infrared) scene simulator is designed. The opticalmechanical structure of its main parts, including projection system, illumination system, and dichroic beamcombiner, are designed in detail. The optical engine adopts telecentric system to illuminate DMD target surface directly, which uses vertical space overall arrangement to avoid interference from different light path. Moreover, the engine uses two smallsize metal plane mirrors to compress illumination light path, so that system integration degree is increased. The beamcombiner is fixed in half kinematics elastic way, we calculate pinchcock’s deflection for the least preload, and its bending stress formed in material. Working temperature of black bodies in two wave bands can be calculated with Matlab, which also fits the proportional relation ψ(T) curve of afteropticalsystem radiation remittance of two wave bands and black body radiation remittance of overall infrared wave band. The simulation testing shows that when black body temperature reaches 850 K, it meets the highest apparent temperature requirement. The contrast ratio of midwave image is 250∶1, and the contrast ratio of longwave image is 14∶1, which satisfies the operating requirements of infrared mid/longwave scene simulator at the present stage.

    参考文献
    相似文献
    引证文献
引用本文

潘越,徐熙平,乔杨.双DMD红外双波段场景模拟器光机结构设计[J].仪器仪表学报,2017,38(12):2994-3002