基于辅助阻抗匹配支路的超声波时差测量系统
DOI:
CSTR:
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

TH814

基金项目:


Ultrasonic time-difference measurement system based on auxiliary impedance matching circuits
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    为了抑制超声波时差测量系统的静态时间差,本文提出了一种基于辅助阻抗匹配支路的新型拓扑结构,并最终基于该 拓扑结构成功研制出了一台超声波时差测量系统样机。 基于样机和自制的换能器,分别进行了不同驱动频率、不同匹配电阻以 及高温工况下(200℃ 、230℃和 260℃ )的静态时间差的测试,并通过实流标定实验验证了整套系统的精度和可行性。 结果表 明,通过辅助阻抗匹配支路的加入能够有效的抑制系统静态时差的均值及其波动范围,且在 200℃ 、230℃ 和 260℃ 的高温环境 下实现了最低-0. 279 ns 的静态时差。 最终,系统在低流量 440 m 3 / h 处精度等级可达 0. 15% ,中、高流量 1 503 ~ 4 397 m 3 / h 范 围内精度可达 0. 05% ,验证了辅助阻抗匹配支路的可行性,为超声波时差测量提供了一种高精度和低静态时差的解决方案。

    Abstract:

    To suppress the static time error of the ultrasonic time-difference measurement system, this paper proposes a new topology based on the auxiliary impedance matching branch, and finally a prototype ultrasonic time-difference measurement system is successfully developed based on this topology. Based on the prototype and the homemade transducer, the static time errors at different driving frequencies, different matching resistances and high-temperature operating conditions (200℃ , 230℃ and 260℃ ) were tested, and the accuracy and feasibility of the whole set of system were verified by the real-flow calibration experiments. The results show that the mean value of the system static time error and its fluctuation range can be effectively suppressed by the incorporation of the auxiliary impedance matching branch, and a minimum static time error of -0. 279 ns is realized under the high-temperature environments of 200℃ , 230℃ and 260℃ . Finally, this system achieves an accuracy level of up to 0. 15% at a low flow rate of 440 m 3 / h, and an accuracy of up to 0. 05% in the range of medium and high flow rates of 1 503 ~ 4 397 m 3 / h, which verifies the feasibility of the auxiliary impedance matching branch, and provides a high-precision and low static time difference solution for ultrasonic time difference measurement.

    参考文献
    相似文献
    引证文献
引用本文

刘 权,赵俊奎,曹建元,邹明伟.基于辅助阻抗匹配支路的超声波时差测量系统[J].仪器仪表学报,2024,45(5):179-187

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2024-09-14
  • 出版日期:
文章二维码